C2W-5620V

1 . WATTAGE :620w

2 . VOLTAGE :90~264VAC FULL RANGE

3 . TEMPERATURE RANGE :OPERATING 0°C~40°C Storage -20°C-80°C

4 . EFFICIENCY :TYPICAL >80% at 25℃ 230V FULL LOAD

5 . HOT-SWAPPABLE / HOT PLUGGABLE REDUNDANCY FUNCTION

6 . DIMENSION :300 * 101 * 84 (D*W*H)mm

Price available upon request.

Product Specifications

Wattage
620w
Dimensions
300 x 101 x 84 (D*W*H) mm
Input Specification

1 . VOLTAGE90~264VAC FULL RANGE

2 . FREQUENCY47~63HZ

3 . INPUT CURRENT

     4A RMS FOR 230VAC

     8A RMS FOR 115VAC

4 . INRUSH CURRENT

     35A MAX. FOR 115 VAC PER MODULE

     70A MAX. FOR 230 VAC PER MODULE

Features

1 . TEMPERATURE RANGE: OPERATING 0°C~40°C STORAGE -20°C~80°C

2 . HOLD UP TIME 16mS MIN. AT FULL LOAD &115 VAC INPUT VOLTAGE

3 . DIELECTRIC WITHSTAND INPUT/OUTPUT 1500 VAC FOR 1 minute

     INPUT TO FRAME GROUND 1500 VAC FOR 1 minute

4 . EFFICIENCY TYPICAL >80% at 25℃ 230V FULL LOAD

5 . POWER GOOD SIGNAL ON DELAY 100mS TO 500mS OFF DELAY 1mS

6 . OVER POWER PROTECTION 110~160% MAX

7 . OVER CURRENT PROTECTION : +12V-55A~80A +5V-27.5A~37.5A +3.3V-27.5A~37.5A

8 . OVER VOLTAGE PROTECTION +12V-13V~15V +5V-5.9V~6.7V +3.3V-3.9V~4.3V

9 . SHORT CIRCUIT: +12V’+5V’+3.3V, AUTO-RECOVERED: 5VSB,-12V

10 . EMI : FCC CLASS B , CISPR 22 CLASS B

11 . REMOTE ON / OFF CONTROL

12 . FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL,I2C

13 . MEET IEC-1000-3-2 CLASS D (ACTIVE PFC)

14. HOT-SWAPPABLE / HOT PLUGGABLE REDUNDANCY FUNCTION

15 . REMOTE SENSING DESIGN

16 . ISOLATION: BUILT-IN THE POWER MODULE

17 . DIMENSION  : 300 * 101 * 84 (D*W*H)mm

18 . COOLING: TWO 40mm DC FANS (MODULE
DC Output Specification
Output VoltageOutput Current Min.Output Current Max.Regulation LoadRegulation LineOutput Ripple & Noice Max.[P-P]
5V

0.5A

25A

value value

50mV

12V

2A

50A

value value

120mV

 

 

       
-12V

0A

0.8A

value value

120mV

3.3V

0.5A

25A

value value

50mV

+5VSB

0A

3.5A

value value

50mV

Remarks:

+5V and +3.3V total output max : 170W

Total output max : 620W

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY REGULATIONS.

How to Order

To place an order, please make an enquiry using the 'Request More Information' form at the bottom of the page and one of our experienced sales team will contact you shortly.

Alternatively, you can call or email us and speak to one of our experienced technical sales team. 

Tel: 01438 842 300
Email: sales@tmc-uk.com

There are no downloads available.

 

Sign Up to Our Free Newsletter for Expert Information & News